Accelerometers

Individual calibration
All PLACID accelerometers are being calibrated in a controlled laboratory environment using traceable calibration equipment complying with ISO17025 standards.
We recommend that all PLACID accelerometers are re-calibrated every year to guarantee an optimized usage.
PLACID Traceable Calibration is performed by our qualified staff and under controlled conditions according to the procedures and standards such as ISO17025.

Quality
All PLACID accelerometers are made of high-quality materials that will ensure long stability and durability, even in harsh condition. PLACID offers 2 years warranty against defective materials and workmanship.
All our accelerometers are made from Stainless steel.

PLACID Accelerometers

Model

Type

Sensitivity 

mV/g

Range (g)

Frequency (Hz)

Temperature range (C)

Excitation (V)

Housing material

Connector type

PQV1050

Single axis

100 mV/g

+/- 50 g

0.5 – 12000

-40 / +120 

+12 / +24 IEPE

Stainless steel

TNC

PQV1050-4

Single axis

40 mV/g

+/- 50 g

0.5 – 12000

-40 / +120 

+12 / +24 IEPE

Stainless steel

TNC

PQV3010

Triaxial

500 mV/g

+/- 10 g

0.5 – 5000

-40 / +125

+12 / +24 IEPE

Stainless steel

M5

PQV3050

Triaxial

100 mV/g

+/- 50 g

0.5 – 7000

-40 / +125

+12 / +24 IEPE

Stainless steel

M5

PQV3500

Triaxial

10 mV/g

+/- 500 g

0.5 – 10000

-40 / +125

+12 / +24 IEPE

Stainless steel

M5

PVSEW mk2

Triaxial

MEMS based

+/- 8g

0.1 – 2000

-20 / +60

N/A

Weatherproof ABS enclosure

PLACID Accelerometer PQV 1050
Single axis 100 mV/g

The PLACID PQV 1050 is used for all forthcoming vibration measurements where only a 1-axis signal is required.

PLACID Accelerometer PQV 1050-4
Single axis 40 mV/g

The PLACID PQV 1050-4 is used for all forthcoming vibration measurements where only a 1-axis signal is required.

Triaxial vibration loggor MEMS PVSEW Mk2

PLACID Accelerometer PSEW mk2
Triaxial, MEMS, Wireless

The PLACID PSEW mk2 is used for vibration monitoring where 3-axis are required and online cloud access with alarms.

PLACID Accelerometer PQV 3010
Triaxial 500 mV/g

The PLACID PQV 3010is an IEPE powered accelerometer. As the output impedance of our IEPE accelerometers is between 100-300 Ohm, no special low-noise cable is required.

PLACID Accelerometer PQV 3050
Triaxial 100 mV/g

The PLACID PQV 3050 is an IEPE powered accelerometer. As the output impedance of our IEPE accelerometers is between 100-300 Ohm, no special low-noise cable is required.

PLACID Accelerometer PQV 3500
Triaxial 10 mV/g

The PLACID PQV 3500 is an IEPE powered accelerometer. As the output impedance of our IEPE accelerometers is between 100-300 Ohm, no special low-noise cable is required.