PLACID Accelerometer PQV 3500 triaxial, 100 mV/g

PLACID Accelerometer

The PLACID PQV 3500 is an IEPE powered accelerometer. As the output impedance of our IEPE accelerometers is between 100-300 Ohm, no special low-noise cable is required.

  • Frequency Range 0.5 – 10000 Hz
  • Measurement Range+/- 500 g
  • Nominal sensitivity 100 mV/g

Download PLACID PQV 3500 Accelerometer Datasheet

Compare

PLACID Accelerometer PQV 3500

TRI-AXIAL SIDE-EXIT CONNECTOR

Basics
The PLACID PQV 3500 is a multi-purpose IEPE accelerometer.

Connectivity
The PLACID PQV 3500 is an IEPE powered accelerometer. As the output impedance of our IEPE accelerometers is between 100-300 Ohm, no special low-noise cable is required.

Uses
The PLACID PQV 3500 is used for all forthcoming vibration measurements where triaxial measurement is required

Individual calibration
All PLACID accelerometers are being calibrated in a controlled laboratory environment using traceable calibration equipment complying with ISO17025 standards.
We recommend that all PLACID accelerometers are re-calibrated every year to guarantee an optimized usage.
PLACID Traceable Calibration is performed by our qualified staff and under controlled conditions according to the procedures and standards such as ISO17025.

Quality
All PLACID accelerometers are made of high-quality materials that will ensure long stability and durability, even in harsh condition. PLACID offers 2 years warranty against defective materials and workmanship.
All our accelerometers are made from Stainless steel.

Performance
Voltage Sensitivity (+/- 5%) 10 mv/g
Measurement Range (g) +/- 500
Measuring range (Hz) 0.5 – 10000 Hz
Measuring Axis (single/triaxial) Triaxial
Maximum Acceleration 50 g
Shock (Overload Limit) 500 g pk
 

Frequency Response

±5% X,Y 5000 Hz ; Z 10000 Hz
±10% X,Y 6000 Hz ; Z 10000 Hz
 

Amplitude Response

±5% X,Y 5000 Hz ; Z 10000 Hz
±10% X,Y 6000 Hz ; Z 10000 Hz
Resonant Frequency 10 kHz
Non-Linearity 1%
Phase Response ±
Residual Noise
Transverse sensitivity ≤5%
Broadband Resolution
Base strain sensitivity
Output Impedance <100Ω
Output Bias Voltage 8 – 12 V
Grounding Cable shielding layer
Spectral Noise ≤300uv
Sensing element PZT5(Piezoelectric ceramics)
Sensing  geometry 20 mm × 20 mm × 18.5 mm
Environmental
Temperature range (Celsius) -10 to +55°C
Electrical
Excitation Voltage (V) 18 to 30 V (Typical value:24 V)
Constant current excitation 2 to 20 mA (Typical Value: 4 mA)
Supply Voltage (Unloaded) 18 to 30 V (Typical value:24 V)
Constant current supply 24 V 4 mA
Physical
Housing material Aviation aluminum
Sealing Crimping
Electrical connector M12
Electrical connection Position Side
Weight 27 g
Accessories
Accessories Supplied Aviation connector M12

SPECIFICATION

 

 

Models / Unit

 

Type

 

Sensitivity (mV/g)

 

Measurement Range (g)

 

Transverse Sensitivity

 

Frequency Range (Hz)

 

Temperature Range (C)

 

Excitation Voltage (V)

 

Housing Material

 

Cable Type

PQV1050  

 

 

 

Single

 

100

 

+/- 50

≤5%  

0.5 – 12000

 

-40 – +120

 

+12 – +24 (IEPE)

Stainless Steel  

TNC

PQV1050-4 40 +/- 50 ≤5% 0.5 – 12000 -40 – +120 Stainless Steel TNC
PQV1500S 10 +/- 500 ≤5% 0.5 – 10000 -40 – +120  

+12 – +30 (IEPE)

Stainless Steel M5
PQV1500T 10 +/- 500 ≤5% 0.5 – 10000 -40 – +120 Stainless Steel M5
PQV3010  

 

Triaxial

500 +/- 10 ≤5% 0.5 – 5000 -40 – +125  

 

+12 – +24 (IEPE)

Stainless Steel M5
PQV3050 100 +/- 50 ≤5% 0.5 – 7000 -40 – +125 Stainless Steel M5
PQV3500 10 +/- 500 ≤5% 0.5 – 10000 -40 – +125 Stainless Steel M5

PLACID is able to customize different products, will quote and provide delivery date according to customer demand