Measurement microphone set PMNP21T (TEDS)

The PLACID PMNP21T Measurement microphone adopts IEPE power supply mode, without polarization voltage, and complies with IEC61672 Type 1

Frequency Range (± 1dB) 10 to 8000 Hz
Frequency Range (± 2dB) 6.3 to 20000 Hz
Dynamic Range: 17 to 136 dB(A)
Nominal Sensitivity: 50 mV/Pa

The PLACID PMNP21T Measurement microphone adopts IEPE power supply mode, without polarization voltage, and complies with IEC61672 Type 1. It can be connected with IEPE power supply signal conditioner, data collector, sound level meter and other testing equipment for precise acoustic measurement, with good phase consistency, suitable for forming a multi-channel measurement system.

Download PLACID PMNP21T Microphone Datasheet

Compare

PLACID PMNP21T (TEDS) Measurement Microphone set

Specifications

The PLACID PMNP21T Measurement microphone adopts IEPE power supply mode, without polarization voltage, and complies with IEC61672 Type 1. It can be connected with IEPE power supply signal conditioner, data collector, sound    level meter and other testing equipment for precise acoustic measurement, with good phase consistency, suitable for forming a multi-channel measurement system.

The PLACID PMNP21T measurement microphone includes PLACID PNP21T preamplifier and PLACID PMP21 1/2″ high-quality prepolarized free field microphone capsule. The PLACID PNP21T preamplifier has built-in TEDS function, supporting data acquisition equipment to directly read microphone information, including model, serial number, sensitivity, etc. The shell of the preamplifier is made of stainless steel, which is suitable for acoustic testing requirements in many occasions.

The frequency response index of PLACID PMNP21T is strictly controlled according to the IEC standard. All microphones have passed the rigorous environmental aging test, making them have the advantages of wide frequency range, wide dynamic range, flat frequency response, long time stability, etc.

Standards

IEC 61094-4:1995 Measurement microphones
Specifications for working standard microphones
GB/T 20441.4-2006 Measurement microphones
Specifications for working standard microphones
IEEE 1451.4

Features

Suitable for precise acoustic test
Frequency range covers most test requirements
Built-in TEDS function
Compact structure and small volume

Design

All PLACID ICCP microphone preamplifiers are designed for ¼”, ½” and 1” condenser microphones. The preamplifiers are optimized to have a flat frequency response which will ensure high quality acoustic measurements.

Self Noise

The electrical circuit has especially been designed to ensure a low self-noise level which typically be much lower than the self-noise of the microphone cartridge.

PLACID PMNP21T

The frequency response index of PLACID PMNP21T is strictly controlled according to the IEC standard. All microphones have passed the rigorous environmental aging test, making them have the advantages of wide frequency range, wide dynamic range, flat frequency response, long time stability, etc.

Daily Usage

Suitable for precise acoustic test
Frequency range covers most test requirements
Built-in TEDS function
Compact structure and small volume

PLACID PMNP21 T
1/2″ FREE FIELD MICROPHONE
Nominal microphone diameter 1/2″
Sound field Free field
Microphone type Prepolarization
Polarization voltage 0 V
Dynamic range 17 to 136 dB
Sensitivity (± 2dB) 50 mV/Pa
Sensitivity (± 2dB) -26 dB ±2dB re 1 V/Pa
Frequency Range (±1 dB): 10 Hz to 8 kHz
Frequency Range (±2 dB): 6.3Hz to 20 kHz
Lower Limiting Frequency (-3 dB) 2 to 4Hz
Cartridge Thermal Noise 16.0 dB(A)
Upper Limit of Dynamic Range (3% Distortion): >146 dB re 20 µPa
Maximum Sound Pressure Level(Peak) 158 dB (peak)
TEDS Compliant Yes
Output impedance <110 Ω
TEDS IEEE 1451.4 V1.0 UDID= I27-0-0-0U
Temperature Range(Operating) −20 to +80°C (−22 to +302°F)
Temperature Coefficient of Sensitivity –0.02 dB/C
Temperature coefficient (- 10 ~ 50 ℃) -0.012 dB/℃
Relative humidity range (no condensation) 0 ~ 98 %RH
Relative humidity coefficient (no condensation) <0.1 dB/%
Static pressure coefficient -0.01 dB/kPa
Constant Current Excitation 3.5 mA to 10 mA
Output Bias Voltage: 12 to 16 VDC
Output Impedance <110 Ohm
Electrical Connector BNC Jack
Venting Rear
Standard IEC 61094-4 WS2F
Power supply 2 to 20mA(IEPE)
Typical operating current 4 mA
Output interface BNC
Weight 35 g

Frequency Response

Dimension

Maintenance

Due to the complex and sensitive physical and acoustic characteristics of the microphone itself, please do not disassemble or modify it by yourself, which may cause irreparable damage, which is not within the warranty scope of the company
For outdoor use, especially in the test scene with wind speed to a certain extent or sand dust, matching windscreen must be used to ensure the measurement accuracy and protect the microphone diaphragm to the greatest extent
During daily use, attention shall be paid to ensure that the liquid will not be sprayed, submerged or dumped on the microphone, otherwise the microphone will be damaged
Please handle with care during use. Don’t beat hard or knock with other hard objects
In case of without test, please do not put the microphone outdoors for a long time, so as not to affect their use effect. Please put the microphone into the packing box for storage in case of lightning weather or long-term non use

Please Click and Download this product datasheet for further information