PLACID Accelerometer PLV 3010 02Y1 triaxial

PLACID Accelerometer

The PLACID PLV 3010 02Y is used for all forthcoming vibration measurements where a triaxial is required.

  • Frequency Range 0.5 – 10000 Hz
  • Measurement Range+/- 500 g
  • Nominal sensitivity 10 mV/g

Download PLACID PLV 3010 02Y1 Accelerometer Datasheet

Compare

PLACID Accelerometer PLV 3010 02Y1 triaxial

TRIAXIAL TOP-EXIT CONNECTOR

Basics
The PLACID PQV 3010 02Y1 is a multi-purpose IEPE accelerometer.

Connectivity
The PLACID PLV 3010 02Y1 is an IEPE powered accelerometer. As the output impedance of our IEPE accelerometers is < than 100 Ohm, no special low-noise cable are required.

Uses
The PLACID PLV 3010 02Y1 is used for all forthcoming vibration measurements where a triaxial is required.

Individual calibration

All PLACID accelerometers are being calibrated in a controlled laboratory environment using traceable calibration equipment complying with ISO17025 standards.
We recommend that all PLACID accelerometers are re-calibrated every year to guarantee an optimized usage.
PLACID Traceable Calibration is performed by our qualified staff and under controlled conditions according to the procedures and standards such as ISO17025.

Quality
All PLACID accelerometers are made of high-quality materials that will ensure long stability and durability, even in harsh condition. PLACID offers 2 years warranty against defective materials and workmanship.
All our accelerometers are made from Stainless steel.

DATASHEET PLACID PLV 3010 02Y1 ACCELEROMETER
GENERAL CHARACTERISTIC
Measurement Range(g) 0.5—10000Hz
Measuring  Axis(single/triaxial) Triaxial
Voltage Sensitivity(±5%) 10 mv/g
Maximum Acceleration ±500 g
Shock (OverloadLimit) 5000 g pk
 

Frequencyresponse

±5% 8000 Hz
±10% 10000 Hz
 

Amplitude Response

±5% 8000 Hz
±10% 10000 Hz
Resonance Frequency ≥70 kHz
Non-Linearity 1%
Temperature Range -40 to +120℃
Transverse Sensitivity ≤5%
Output Impedance ≤100 Ω
Output BiasVoltage 8-12 VDC
Grounding Cable shielding layer
Sensing elements Piezoelectric ceramics
 

Sensing Geometry

11mm x 11mm x 11mm

 

DATASHEET PLACID PLV 3010 02Y1 ACCELEROMETER
POWER REQUIREMENT
Excitation Voltage(V) Typical 24 VDC
Constant CurrentExcitation Typical 4 mA
Supply Voltage(Unloaded) 20 – 30 VDC
Constant CurrentSupply 2 – 20 mA

 

PHYSICAL CHARACTERISTICS
Housing Material Titanium Alloy
Sealing Crimping
Weight 4.8 gram
ElectricalConnector 1/4-28 4-Pin
Electrical ConnectionPosition Side